国产性爱高清乱伦幼_国产少妇3p视频_歐美性愛網址_精品国产鲁一鲁一区二区张丽_国家一级精品黄小说久久久_久久久国产无码A√_一级a婬片试看3o分钟囗交_亚洲 暴力 无码 丝袜_乱伦日屄网站_天堂有码一区_AAA一级黄片搜索_老熟女video91_天天干,天天操,天天B_图产一二三区精品视频_91久久欧美极品少妇XXXXⅩ麻豆

Industry information Calculation of cooling area of sampling cooler制造廠型號(hào)參數(shù)
Your location : Home > News > Industry information

Calculation of cooling area of sampling cooler

time:2023-11-25 22:44:54Views:

Calculation of cooling area of sampling cooler


1: If the sample flow rate, cooling water temperature, and initial conditions of the sample are known, then the cooling surface required for the sampling cooler


The product can be obtained from equation (A1):


A=f ? 1.0029/3600 Δ Tm ? U (A1)


Equation - A - required cooling area, m2;


F - Sample flow rate, L/h;


Δ Tm - average temperature difference, ℃;


U - Overall heat exchange coefficient (U=200 for double-layer spiral tubes and immersion coolers).


When the sample is superheated steam, for every 100 ℃ superheat, the cooling area calculated by equation (A1) should be based on


On the basis of this, it will increase by 12.6%.

微信圖片_20170908141357.jpg

2: The average temperature difference can be obtained from equation (A2):


Δ Tm=[(t1-T2) - (t2-T1)]/[L (t1-T2)/(t2-T1)] (A2)


Equation-


Δ Tm - average temperature difference, ℃;


T1- cooler sample temperature, ℃;


T2- cooler sample temperature, ℃;


T1- cooler - cooling water temperature, ℃;


T2- Cooling water temperature at the outlet of the cooler, ℃.


3: The spiral tube of the cooler can be composed of a continuous coil with the required cooling area, or it can be arranged inside and outside of two sets of spiral tubes.


產(chǎn)品動(dòng)態(tài)

Calculation of cooling area of sampling cooler制造廠Copyright ? 2012-2023 Lianyungang Lingdong Electromechanical Equipment Co., Ltd all rights reserved

Tel

0518-85370171